Product Details:
|
|
Place of Origin: | Sweden |
---|---|
Brand Name: | ABB Module |
Certification: | CO.CQ |
Model Number: | SDCS-IOB-22 3BSE005177R1 |
Payment & Shipping Terms:
|
|
Minimum Order Quantity: | 1 |
Price: | inquiry |
Packaging Details: | new and original with factory sealed |
Delivery Time: | today |
Payment Terms: | T/T |
Supply Ability: | 10 pieces a day |
Detail Information |
|||
Manufacture Year: | 2016 | Control System: | ABB Module System |
---|---|---|---|
Application: | Nuclear Power Plant | Lead Time: | In Stock |
Description: | SDCS-IOB-22 3BSE005177R1 ABB SDCS-IOB-22 Connection Interface | Weight: | 4lbs |
High Light: | abb plc,advant ocs |
Product Description
ABB Module SDCS-IOB-22 3BSE005177R1 ABB SDCS-IOB-22 Connection Interface NEW in sealed box
Product Description:
It has to be taken into consideration, that in this application the M terminal of the basic unit 07 KT 94 is
the reference potential. AGND1 is not dimensioned for carrying the sum of the sensor currents. The value of the range underflow is stored. If the ope circuit monitoring is configured, the open-circuit event is displayed by the red LED Ovl as long as it is present. In the PLC system an error message is stored (FK4, error number 9). The following figure shows the connection of 2-pole passive- type analog sensors 4...20 mA. If the analog current sensors 4...20 mA are powered from a separate power supply unit, the reference potentials 0V (of the separate power supply unit and the power supply unit for the 07 KT 94) must be interconnected to each other.In the above example, the AGND terminal remains
unused.
Related Product Recommendation:
3BSE00638R1 | AV41 | DSQC227 YB560103-CE |
3BSE006385R1 | AV42 | DSQC223 YB560103-CD |
3BSE013243R1 | AV43 | DSQC205 YB560103-BK |
3BSE013284R1 | AV97 | DSQC201 YB560103-BD |
3BSE012632R1 | AV98 | DSQC104 YB560103-AD/1 |
3BSE001449R1 | AW01 | DSQC 633A YB560103-AB |
3BUR000101R1 | AW02 | DSQC 539 6369901-104 |
3BUR980023R1 | AW03 | DSQC 352A 3HAC 031851-001 |
3BSE002224R1 | AW05 | DSSR170 48990001-PC 3HAC14265-1 |
3BSE002253R1 | DAI01 | DSSB146 |
3BSE004447R1 | DAI04 | DSTD150A 48980001-AP/1 DSSB146*BAT2C |
3BSE003785R1 | DAI05 | DSTD132 |
3BUR000118R3 | DAO01 | DSTD108P 57160001-UH |
3BSC950030R1 | DCO01 | DSTD108 5716001-FX |
3BSE003785R1 | DCP02 | DSTD 110A 3BSE018333R1 |
3BSC950022R5 | PAA02 | DSTC454 5751017-F 57160001-ABD/ABW |
3BSC950004R1 | PAB02 | DSTC190 57520001-ER 57160001-TZ |
3BHT300007R1 | PAR01 | DSTA180 |
3BSC950138R1 | DDO02 | DSTA160 |
3BSC950130R1 | XN05 | DSTA131 57120001-CV 57120001-ET |
3BSC950158R1 | XN06 | DSTA131 57120001-AH |
3BSC950251R1 | XP01 | DATX130 3ASC25H214 57120001-CV |
3BSE008526R1 | XU01 | DAPC100 |
1SBP260103R1001 | XU02 | DAI05 3ASC25H203 |
1SBP260101R1001 | XU03 | DAI03 P37131-4-0336025 |
GJV3074365R1 | XU04 | DCP02 |
GJV3074366R1 | XU12 | 3ASU21C110 LU6278 DCU30/7 P-37211-4-0369654 |
Product's Character:
Differential inputs are very useful, if analog sensors are used which are remotely non-isolated (e.g. the minus terminal is remotely earthed). Since the earthing potential is not exactly the same as
AGND1, it has to be measured bipolar in order to compensate measuring errors. Additionally, in case of singlepole configuration, AGND1 would be connected directly to the remote earth potential. This would cause inadmissable (and possibly dangerous) earthing loops. In all configurations using differential inputs two adjacent analog inputs belong together (e.g. EW 6,00 and EW 6,01). For configuration, both inputs must be configured for the desired operating mode, see configuration table Fig. The measured value is calculated by subtraction. The value of the channel with the lower address is subtracted
GJR5143200R0001 35 EK 91 35 EK 91 Bus Coupler Unit ABB
GJR5143600R0001 35 TP 90 ABB Carrier Board ABB
GJR5143700R0001 35 SK 96 R1 35 SK 96 R1 Cable ABB
GJR5144900R0001 35 ST 90 35 ST 90 Connector ABB
GJR5145000R0201 35AE92 4 Channel Axis Module ABB
GJR5145000R0301 35ZE93C ABB Module ABB
GJR5145010R0001 35 ZP 93 35 ZP 93 Interface Module ABB
GJR5145020R0001 35 DS 91 35 DS 91 Interface Module ABB
GJR5145800R0001 35 EB 92, GJR5145800R1 35 EB 92 Digital Input Module ABB
GJR5146600R0101 35 ZE 94G, 35 ZE 94F, 35 ZE 94 35 ZE 94 CPU Processor Board ABB
GJR5146900R0101 35 CS 91 35 CS 91 Coupler Circuit Board ABB
GJR5210000R1 07 ET 40 R1 07ET40R1 Cardfile ABB
GJR5217100R201 07 TZ 82 B BBC Module ABB
GJR5217500R0002 07ET83B B Rack ABB
GJR5218500R0002 21 Slot Cardfile ABB
GJR5219100R0201 Rack ABB
GJR5221100R1 07YS82 07 YS 82 Output Module ABB
GJR5230400R1 07 BT 84 R1 07 BV 84 Module ABB
GJR5230500R1 07BV84,07BT82 07 BV 84 Module ABB
GJR52311200R1 07AE83 07 AE 83 Analog Input Module ABB
GJR5231600R1012 07 ZV 86 Processing Module Brown Boveri (BBC)
GJR5250000R0101 07KR91 CS31 Central Unit - 90 Series ABB
GJR5250000R0151 07KR91 CS31 Central Unit ABB
GJR5250000R0202 07KR91, 07KR91D, 07KR91B Central Processing Unit -120/230 Vac ABB
GJR5250000R0252 07 KR 91 07KR91 Central Processing Unit-24 VDC ABB
GJR5250000R0303 07KR91 Advant Controller 31 ABB
GJR5250000R0353 07KR91B 07KR91 Basic Unit ABB
GJR5250200R1 07SK90R1, GJR 525 0200 R0001 07SK90R1 Programming Cable - 5 meters ABB
GJR5250500R0101 07KT92 Central Unit - 90 Series ABB
GJR5250500R0202 07KT92, 07KT92 D, 07KT92C 07KT92 Central Processing Unit ABB
GJR5250500R0262 07KT92 07KT92 Central Processing Unit - 90 Series ABB
GJR5250500R0902 07 KT 92 07KT92 Central Processing Unit ABB
GJR5250500R5101 23KT92, RTU510 RTU510 23KT92 Unit ABB
GJR5250800R0202 07 DO 90-S Digital Output Unit ABB
The use of the product:
1.emission reduction
2. new and original
3.1 year warranty
Our advantages:
1.Provides the lowest Total Cost of Ownership (TCO)
2.emission reduction
3.Avoid unplanned downtime
1.Q:How long warranty does Moore can provide ?
A: Moore can provide 1 year warranty !
2.Q:Does Moore test the products before shipping ?